12V UPS System with Dual 18650 Li-ion Battery Backup and Voltage Regulation
View and Edit Project In Cirkit Designer
Circuit Documentation
Summary
The circuit in question appears to be a power supply system with a UPS (Uninterruptible Power Supply) module, designed to provide a stable DC output from an AC power source while also being capable of switching to battery backup in the event of a power outage. The circuit includes a 12V 5A power supply, two sets of 18650 Li-ion batteries, two XL4016 DC-DC converters, an AC wire connection, and a toggle switch for manual control of the AC input.
Component List
UPS Module
- Description: A module designed to switch between mains power and battery backup to provide an uninterrupted power supply.
- Pins: DC-, DC+, BAT+, BAT-, OUT+, OUT-
POWER SUPPLY 12V 5AMP
- Description: A power supply unit that converts 220V AC to a 12V-24V DC output.
- Pins: 220V Positive Pole (AC), 220V Negative Pole (AC), GND, GND (DC), 12V-24V Output (DC)
XL4016 (x2)
- Description: A DC-DC converter module capable of stepping down voltage with high efficiency.
- Pins: In+, In-GND, Out-GND, Out+
AC Wire
- Description: A wire used to connect the circuit to the AC mains.
- Pins: Line, Earth, Neutral
18650 Li-ion Battery x 2 (x2)
- Description: Two sets of 18650 Li-ion batteries providing a rechargeable power source.
- Pins: +, -
Toggle Switch SPST
- Description: A single-pole single-throw switch used to manually open or close the circuit.
- Pins: L1, COM
Wiring Details
UPS Module
- DC-: Connected to XL4016 In-GND and POWER SUPPLY GND (DC)
- DC+: Connected to XL4016 In+ and POWER SUPPLY 12V-24V Output (DC)
- BAT+: Connected to 18650 Li-ion Battery + and XL4016 Out+
- BAT-: Connected to 18650 Li-ion Battery - and XL4016 Out-GND
- OUT+: Connected to XL4016 In+
- OUT-: Connected to XL4016 In-GND
POWER SUPPLY 12V 5AMP
- 220V Positive Pole (AC): Connected to Toggle Switch COM
- 220V Negative Pole (AC): Connected to AC Wire Neutral
- GND: Connected to AC Wire Earth
- GND (DC): Connected to UPS Module DC- and XL4016 In-GND
- 12V-24V Output (DC): Connected to UPS Module DC+ and XL4016 In+
XL4016
- In+: Connected to UPS Module DC+ and OUT+
- In-GND: Connected to UPS Module DC- and OUT-
- Out-GND: Connected to UPS Module BAT- and 18650 Li-ion Battery -
- Out+: Connected to UPS Module BAT+ and 18650 Li-ion Battery +
AC Wire
- Neutral: Connected to POWER SUPPLY 220V Negative Pole (AC)
- Earth: Connected to POWER SUPPLY GND
- Line: Connected to Toggle Switch L1
18650 Li-ion Battery x 2
- +: Connected to UPS Module BAT+ and XL4016 Out+
- -: Connected to UPS Module BAT- and XL4016 Out-GND
Toggle Switch SPST
- L1: Connected to AC Wire Line
- COM: Connected to POWER SUPPLY 220V Positive Pole (AC)
Documented Code
No microcontroller code has been provided for this circuit. If the circuit includes a microcontroller or any programmable device, please provide the relevant code for documentation.