Dual 5V Power Supply Distribution Circuit with Toggle Switch Control
View and Edit Project In Cirkit Designer
Circuit Documentation
Summary of the Circuit
This circuit appears to be a power distribution system that takes 220V AC from a wall plug point and converts it to a lower DC voltage using two 5V 5A power supplies. The DC outputs from the power supplies are then distributed to various points in the circuit via a 12-way dual row micro fit connector. Additionally, there are toggle switches that may be used to control the flow of power or to act as an interface for user input.
Component List
POWER SUPPLY 5V 5AMP
- Description: A power supply unit that converts 220V AC input to a 5V 5A DC output.
- Pins:
- 220V Positive Pole (AC)
- 220V Negative Pole (AC)
- GND
- GND (DC)
- 12V-24V Output (DC)
AC Wall Plug Point
- Description: An interface for connecting the circuit to an AC power source.
- Pins:
- E (Earth)
- N (Neutral)
- L (Live)
12 Way Dual Row Micro Fit
- Description: A connector used for distributing power and signals within the circuit.
- Pins: 12, 6, 11, 5, 10, 4, 9, 3, 8, 2, 7, 1
Toggle Switch
- Description: A switch that can open or close the circuit, controlling the flow of electricity.
- Pins:
- Vcc
- Sig
- Gnd
Wiring Details
POWER SUPPLY 5V 5AMP
- 12V-24V Output (DC): Connected to pin 12 of the 12 Way dual row micro fit connector.
- GND (DC): Connected to pins 6, 4 of the 12 Way dual row micro fit connector and Gnd pins of both Toggle Switches.
- 220V Positive Pole (AC): Connected to the L pin of the AC wall plug point.
- 220V Negative Pole (AC): Connected to the N pin of the AC wall plug point.
- GND: Connected to the E pin of the AC wall plug point.
AC Wall Plug Point
- E (Earth): Connected to the GND pins of the POWER SUPPLY 5V 5AMP units.
- N (Neutral): Connected to the 220V Negative Pole (AC) pins of the POWER SUPPLY 5V 5AMP units.
- L (Live): Connected to the 220V Positive Pole (AC) pins of the POWER SUPPLY 5V 5AMP units.
12 Way Dual Row Micro Fit
- Pin 12: Connected to the 12V-24V Output (DC) of one POWER SUPPLY 5V 5AMP unit.
- Pins 6, 4: Connected to the GND (DC) of both POWER SUPPLY 5V 5AMP units.
- Pin 5: Connected to the Vcc pin of one Toggle Switch.
- Pin 11: Connected to the Vcc pin of the other Toggle Switch.
Toggle Switch
- Vcc: Connected to pin 5 of the 12 Way dual row micro fit connector for one switch and pin 11 for the other switch.
- Gnd: Connected to the GND (DC) of the POWER SUPPLY 5V 5AMP units.
Documented Code
There is no code provided for any microcontrollers in the circuit. If there were microcontrollers or other programmable devices included, this section would contain the documented code for each device, including descriptions of the functionality implemented by the code and any relevant algorithms or logic used.